Shodex™ IC series

    The Shodex™ IC series of ion chromatography columns are made of either polyhydroxymethacrylate, polyvinyl alcohol,Styrene divinylbenzene copolymer or silica base material and are available with either quaternary ammonium, carboxyl or sulfo functional groups for suppressor or non-suppressor IC methods.

The Shodex™ IC series of ion chromatography columns are made of either polyhydroxymethacrylate, polyvinyl alcohol, styrene divinylbenzene copolymer or silica base material and are available with either quaternary ammonium, carboxyl or sulfo functional groups for suppressor or non-suppressor IC  methods.

There are two types of ion chromatography: non-suppressor method and suppressor method. While the suppressor method requires a suppressing module, the non-suppressor method can be used for ion analysis by simply connecting an electro-conductivity detector to an all-purpose LC system.

Shodex provides columns for cation/anion analysis for both non-suppressor and suppressor methods. They also provide columns for analyzing transition metal ions and rare earth metal ions using the post-column reaction system. Column selection can thus be made based on your analysis needs and type of ions.

Ion Chromatography Columns (Anion Analysis)

Shodex™ NI-424 and Shodex™ I-524A

  • Columns for anion analysis with non-suppressor method
  • NI-424 supports simultaneous analysis of fluoride and phosphate ions

Shodex™ SI-90 4E & Shodex™ SI-50 4E

  • Columns for anion analysis with suppressor method
  • Suitable for the quantitative analysis of fluoride ion
  • SI-50 separates target inorganic anions from organic acids
  • Not interfered by the system peak derived from carbonate

Shodex™ SI-35 4D & Shodex™ SI-52 4E

  • Columns for the analysis of oxyhalides
  • SI-35 supports rapid analysis of oxyhalides and general inorganic ions
  • SI-52 supports simultaneous analysis of oxyhalides and general inorganic ions

Ion Chromatography Columns (Cation Analysis)

Shodex™ YS-50

  • High performance type of YK-421
  • Applicable to both suppressor and non-suppressor methods
  • Peak shape is sharper, especially for divalent cation analysis
  • Supports the analysis of alkylamines and transition metals

Shodex™ YK-421

  • Column for cation analysis with non-suppressor method
  • Simultaneous analysis of monovalent and divalent cations
  • Suitable for separation of alkylamines

Shodex™ Y-521

  • Column for cation analysis with non-suppressor method
  • For the separation of monovalent or divalent cations

Shodex™ T-521

  • Column for transition metal ion analysis
  • High sensitivity analysis is achieved by post column color reaction method